ENOVIAVPM

This page deals with the options concerning:

VPM Interoperability Administration

Selecting the Disable CATIAV5 VPM DB connection check box allows you to remove the database connection required when using CATIA V5 with VPM V4. This avoids problems related to the security and administration due to the initialization of such database connection.  

There are three push buttons in this section:

  • Selecting the Database Administration option lets you define the parameters for connection to the CDM databases you wish to use (see "Connecting an ORACLE or DB2 Database to Your CATIA Version 5 Environment" in the ENOVIAVPM User's Guide).
  • Selecting the Database Server Dictionary option lets you define a CDM dictionary associated with a server.
  • Selecting the ENOVIAvpm/Product Structure Mapping option lets you map CDM and assembly attributes (see "Mapping CDM and Assembly Attributes" in the ENOVIAVPM User's Guide).
  • Selecting ENOVIAvpm/Product Structure Nodes Customisation option lets you customize the display of nodes in Catia by selecting required attributes to load from VPMV4

PSN Display Options

  • Selecting the Automatic Highlight in PSN check box sets the automatic highlight for the identification of models in a PSN graph from a Version 5 session and vice-versa. This means that whenever you select one or more models in a PSN graph they are automatically highlighted in the Version 5 session. When selected in a Version 5 session, they are automatically highlighted in the corresponding PSN graph.
    If you do decide to use this option you should be aware that performance will be adversely affected.

Customize Session Building

  • Selecting the Load all EnoviaVPM properties check box means that when a session is built all the properties visualized in VPM that have not been mapped will be loaded as user properties.
    • If you do decide to use this option you should be aware that performance will be adversely affected.
    • When the cache mode is on, the user properties in the Product: Added Properties section of the Properties dialog box are not visible because the Part reference is not loaded.
  • Selecting the Disable Applicative Object management check box speeds up performance.
    If you do decide to use this option you should be aware that V5 applicative objects such as publications, constraints, etc. will neither be saved nor stored in the database.

VPM Cache Management

Selecting the Work with the V4 VPM cache system check box allows you to:
  • Use the cache system and provide the location of the V4 local cache in the field VPM Cache path.
  • Set percentage of use cache to be set. Selecting the Manual cache cleaning check box allows you to to set the percentage of usage.

VPM Save Panel Management  

  • Selecting the Disable the VPM Save Commit Panel check box enables you to dispense with the Save Commit dialog box.
  • Selecting the Disable the VPM Save Report Panel check box enables you to dispense with the Save Report dialog box.

VPM LCA Vault Save


If you select the Enable Direct V5 Vault Save check box, then during save, CATIA will first check if VPM supports direct save into LCA vault by CV5. VPM will save data to LCA vault if this check box is clear.

FBDI Panel Management

  • Selecting the Ask before overwrite existing parts check box displays a message before writing on the existing part from the database.
  • Selecting the Never overwrite existing parts check box does not allow you to overwrite the existing parts.